D09P82C6GX8CLF vs L177HDAH26S
| Part Number |
|
|
| Category | D-Sub Connectors | D-Sub Connectors |
| Manufacturer | Amphenol ICC (FCI) | Amphenol ICC (Commercial Products) |
| Description | CONN DSUB PLUG 9POS R/A PRESSFIT | CONN D-SUB HD RCPT 26POS STR |
| Package | - | - |
| Series | Delta D | HD |
| Features | Board Guide, Grounding Indents | - |
| Mounting Type | Board Edge, Through Hole, Right Angle | Free Hanging (In-Line) |
| Termination | Press-Fit | Solder Cup |
| Current Rating | 5A | 3A |
| Contact Finish | Gold | Gold |
| Number of Positions | 9 | 26 |
| Connector Type | Plug, Male Pins | Receptacle, Female Sockets |
| Contact Finish Thickness | 30µin (0.76µm) | 16µin (0.40µm) |
| Number of Rows | 2 | 3 |
| Connector Style | D-Sub | D-Sub, High Density |
| Contact Type | Signal | Signal |
| Flange Feature | Housing/Shell (4-40) | Cable Side (4-40) |
| Shell Material, Finish | Steel, Tin Plated | Steel, Tin Plated |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 |
| Shell Size, Connector Layout | 1 (DE, E) | 2 (DA, A) High Density |
-
1. What is a D-SUB connector
The name of the D-SUB connector comes from the D-shaped appearance of its plug. It is a double-row cable connector widely used in computer, industrial automation and communication fields. This connector consists of two parts: a plug and a socket. It is connected through pinholes and pins. It can transmit video, audio and digital signals and provide a large number of grounding points.
The D-SUB connector is a compact and versatile connector mainly used to support power, analog, RF or digital signal transmission. It has a variety of models, options and accessories and is a very economical interconnection solution. -
2. Problems caused by poor contact of D-SUB connectors
Performance: increased contact resistance, circuit breakage, contact curtain movement, etc.
Causes: inadequate connection, insufficient contact area, dirt, corrosion, oxidation, etc.
Solution: Re-plug the connector, clean the connection part (use alcohol or other cleaning agents), replace the contact or connector. -
3. D-SUB connector insulation is poor
Performance: short circuit, insulation resistance is too poor.
Cause: high humidity in the use environment, serious pollution, water or other liquids penetrate into the insulator, etc.
Solution: Improve the use environment, clean the inside of the insulator, and replace the insulator. -
4. FAQ of D-SUB Connector
D-SUB connector connection is poor
Performance: shell damage, bayonet connector loose or stuck after plugging.
Cause: internal defects of the connector, external force damage.
Solution: Check and repair internal defects of the connector and avoid external force damage.
D-SUB connector oxidation What are the manifestations?
Performance: increased contact resistance.
Cause: environmental factors and current effects.
Solution: Clean and maintain the connector regularly, and use a protective cover to avoid pin exposure.
What problems are caused by deformation of D-SUB connector?
Performance: Affects contact area and stability.
Cause: Mechanical pressure or temperature change.
Solution: Avoid excessive mechanical pressure and check connector status regularly.