F380J106MMAAH2 vs T520A226M010ATE080

Part Number
F380J106MMAAH2
T520A226M010ATE080
Category Tantalum - Polymer Capacitors Tantalum - Polymer Capacitors
Manufacturer KYOCERA AVX KEMET
Description CAP TANT POLY 10UF 6.3V 0603 CAP TANT POLY 22UF 10V 1206
Package Cut Tape (CT) Tape & Reel (TR)
Series F38 KO-CAP® T520
Type Molded Molded
Features General Purpose General Purpose
Operating Temperature -55°C ~ 105°C -55°C ~ 105°C
Mounting Type Surface Mount Surface Mount
Package / Case 0603 (1608 Metric) 1206 (3216 Metric)
Tolerance ±20% ±20%
Size / Dimension 0.063" L x 0.033" W (1.60mm x 0.85mm) 0.126" L x 0.063" W (3.20mm x 1.60mm)
Voltage - Rated 6.3 V 10 V
Lead Spacing - -
Ratings - -
Height - Seated (Max) 0.035\" (0.90mm) 0.071\" (1.80mm)
Capacitance 10 µF 22 µF
ESR (Equivalent Series Resistance) 200mOhm @ 100kHz 80mOhm @ 100kHz
Lifetime @ Temp. 1000 Hrs @ 85°C 2000 Hrs @ 105°C
Manufacturer Size Code M A
Polymer Capacitors: Advantages & Applications
2024-09-09 21:28:16, Polymer Capacitors: Advantages & Applications
Polymer capacitors are advanced electrical components made with a solid electrolyte instead of a liquid one.
  • 1. What is the difference between aluminum and tantalum capacitors?

    Material: Aluminum capacitors use aluminum foil as the electrode material; tantalum capacitors use tantalum metal.

    Performance: Tantalum capacitors generally have better high temperature performance, higher capacitance density per unit volume, and lower ESR.

    Price: In general, tantalum capacitors cost more than aluminum capacitors.

  • 2. What special precautions must be taken when installing tantalum polymer capacitors?

    Ensure correct polarity connection: Incorrect polarity will cause immediate damage.

    Pay attention to the operating temperature range: Avoid exceeding the recommended operating temperature range.

    Protection during welding: Avoid overheating to protect components from damage.

    ESD protection: Take appropriate anti-static measures during handling.

  • 3. What causes tantalum polymer capacitors to fail?

    Overvoltage operation: Exceeding the rated voltage may cause internal breakdown.

    Reverse bias: Connecting the positive and negative terminals in reverse may cause immediate damage.

    Overheating: Prolonged exposure to high temperature environments can affect performance and even cause failure.

    Mechanical damage: Damage may also be caused by external impact or pressure.

  • 4. What is the difference between wet and dry tantalum capacitors?

    Wet: An early type of tantalum capacitor that contains a liquid electrolyte, which is less common now.

    Dry: A modern version that uses a solid electrolyte (such as manganese dioxide or conductive polymer) for better stability and safety.

Shopping Cart Tel: +86-755-28503874 Email: [email protected] Skype: +8615019224070, annies65, +8615118125813 QQ: 568248857, 827259012, 316249462 Mobile: +8615019224070, +8615118118839, +8615118125813 WeChat: Send Message