F931C685MAA vs F921A105MPA

Part Number
F931C685MAA
F921A105MPA
Category Tantalum Capacitors Tantalum Capacitors
Manufacturer KYOCERA AVX KYOCERA AVX
Description CAP TANT 6.8UF 20% 16V 1206 CAP TANT 1UF 20% 10V 0805
Package -Reel® Cut Tape (CT)
Series F93 F92
Type Molded Molded
Features General Purpose General Purpose
Operating Temperature -55°C ~ 125°C -55°C ~ 125°C
Mounting Type Surface Mount Surface Mount
Package / Case 1206 (3216 Metric) 0805 (2012 Metric)
Tolerance ±20% ±20%
Size / Dimension 0.126" L x 0.063" W (3.20mm x 1.60mm) 0.079" L x 0.049" W (2.00mm x 1.25mm)
Voltage - Rated 16 V 10 V
Lead Spacing - -
Ratings - -
Height - Seated (Max) 0.071\" (1.80mm) 0.039\" (1.00mm)
Capacitance 6.8 µF 1 µF
ESR (Equivalent Series Resistance) 3.5Ohm @ 100kHz 12Ohm
Lifetime @ Temp. 2000 Hrs @ 125°C -
Failure Rate - -
Manufacturer Size Code A P
Tantalum Capacitor: All Things You Need to Know
2024-09-03 21:29:25, Tantalum Capacitor: All Things You Need to Know
What is Tantalum Capacitor? Tantalum capacitors are small in size and can achieve large capacitance products, is first developed by the United States Bell Laboratories in 1956, its performance is excellent.
  • 1. Disadvantages of tantalum capacitors

    The price is relatively high.
    If used improperly or the circuit design is defective, it may fail, including explosion.
    It is polarity sensitive and can only work in the specified direction.
    It may fail easily under certain conditions (such as overvoltage, surge current).

  • 2. Will tantalum capacitors deteriorate?

    Yes, tantalum capacitors may gradually lose some of their performance when stored for a long time or in adverse environments.
    For example, long-term exposure to high temperature and humidity may cause the electrolyte to evaporate or chemically change.

  • 3. Can I use ceramic capacitors instead of tantalum capacitors?

    It depends on the specific situation. If the size, ESR requirements are not high and a specific capacitance value is not required, you can consider replacing it.
    But be aware that there are differences in physical properties between the two, and direct replacement may affect the working state of the circuit.

  • 4. What special precautions must be taken when installing tantalum capacitors?

    Ensure the correct polarity connection.
    Be careful not to exceed the rated voltage.
    Use appropriate fuses or other protective devices to prevent overcurrent.
    Consider heat dissipation design to avoid local overheating.