FCE17A15SC45B vs FCE17A15SA45B

Part Number
FCE17A15SC45B
FCE17A15SA45B
Category D-Sub Connectors D-Sub Connectors
Manufacturer Amphenol ICC (Commercial Products) Amphenol ICC (Commercial Products)
Description CONN D-SUB RCPT 15POS R/A SOLDER CONN D-SUB RCPT 15POS R/A SOLDER
Package - -
Series FCE17 FCE17
Features Filter, Mounting Brackets Filter, Mounting Brackets
Mounting Type Through Hole, Right Angle Through Hole, Right Angle
Termination Solder Solder
Current Rating 5A 5A
Contact Finish Gold Gold
Number of Positions 15 15
Connector Type Receptacle, Female Sockets Receptacle, Female Sockets
Contact Finish Thickness 15µin (0.38µm) 15µin (0.38µm)
Number of Rows 2 2
Connector Style D-Sub D-Sub
Contact Type Signal Signal
Flange Feature Board Side (4-40) Housing/Shell (4-40)
Shell Material, Finish Steel, Tin Plated Steel, Tin Plated
Material Flammability Rating UL94 V-0 UL94 V-0
Shell Size, Connector Layout 2 (DA, A) 2 (DA, A)
  • 1. Features of D-SUB connector

    1. Easy plugging and unplugging: The D-SUB connector adopts a push-pull plug-in design, which is convenient and fast, and can quickly connect and disconnect the circuit.
    2. Reliable contact: The contact of the D-SUB connector is made of high-quality metal material, which is precisely processed and gold-plated, and has good conductivity and long service life.
    3. Wear resistance: The contact of D-SUB connector is made of wear-resistant material, which can withstand frequent plugging and unplugging and long-term use, and is not easy to be damaged.
    4. Multiple specifications: D-SUB connectors have multiple specifications, suitable for different cables and sockets, and the appropriate specifications can be selected according to actual needs.
    5. High reliability: The design of D-SUB connectors focuses on reliability. After strict quality control and testing, it can ensure that there will be no problems such as poor contact or short circuit during use.

  • 2. Problems caused by poor contact of D-SUB connectors

    Performance: increased contact resistance, circuit breakage, contact curtain movement, etc.

    Causes: inadequate connection, insufficient contact area, dirt, corrosion, oxidation, etc.
    Solution: Re-plug the connector, clean the connection part (use alcohol or other cleaning agents), replace the contact or connector.

  • 3. ‌D-SUB connector insulation is poor

    Performance: short circuit, insulation resistance is too poor.

    Cause: high humidity in the use environment, serious pollution, water or other liquids penetrate into the insulator, etc.
    Solution: Improve the use environment, clean the inside of the insulator, and replace the insulator.

  • 4. FAQ of D-SUB Connector

    ‌What is the reason for no signal in D-SUB connector?
    Performance: No signal.

    Solution: Check whether the signal cable is plugged in properly and ensure stable connection. 3.

    ‌‌D-SUB connector causes the monitor to fail to display.
    Performance: The monitor cannot display.
    Solution: Adjust the computer resolution to the highest resolution supported by the monitor.

    ‌‌What is the reason for poor connection of D-SUB connector?
    Performance: Poor connection.

    Cause: The pin is exposed and easily damaged.
    Solution: Use a protective cover to avoid pin exposure and operate carefully.

Shopping Cart Tel: +86-755-28503874 Email: [email protected] Skype: +8615019224070, annies65, +8615118125813 QQ: 568248857, 827259012, 316249462 Mobile: +8615019224070, +8615118118839, +8615118125813 WeChat: Send Message