INA185A3IDRLT vs INA185A1IDRLT
| Part Number |
|
|
| Category | Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps | Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps |
| Manufacturer | Texas Instruments | Texas Instruments |
| Description | IC CURR SENSE 1 CIRCUIT SOT563 | IC CURR SENSE 1 CIRCUIT SOT563 |
| Package | Tape & Reel (TR) | -Reel® |
| Series | - | - |
| Operating Temperature | -40°C ~ 125°C (TA) | -40°C ~ 125°C (TA) |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | SOT-563, SOT-666 | SOT-563, SOT-666 |
| Supplier Device Package | SOT-563 | SOT-563 |
| Current - Supply | 200µA | 200µA |
| Output Type | Rail-to-Rail | Rail-to-Rail |
| Number of Circuits | 1 | 1 |
| Voltage - Supply, Single/Dual (±) | 2.7V ~ 5.5V | 2.7V ~ 5.5V |
| Current - Output / Channel | - | - |
| -3db Bandwidth | - | - |
| Amplifier Type | Current Sense | Current Sense |
| Current - Input Bias | 75 µA | 75 µA |
| Voltage - Input Offset | 25 µV | 100 µV |
| Slew Rate | 2V/µs | 2V/µs |
| Gain Bandwidth Product | 150 kHz | 350 kHz |
-
1. What is the difference between an instrumentation amplifier and an operational amplifier?
Instrumentation amplifiers integrate multi-stage operational amplifiers for precise amplification of differential signals, while operational amplifiers are more versatile and can perform a wide range of analog signal processing tasks. Instrumentation amplifiers have higher input impedance and better common mode rejection.
-
2. What is Common Mode Rejection Ratio (CMRR) and why is it important for instrumentation amplifiers?
CMRR indicates an instrumentation amplifier's ability to suppress common mode signals, with higher values being better. A high CMRR is especially important in noisy environments to ensure that the amplifier primarily amplifies differential signals and is not affected by common mode interference.
-
3. What is the effect of the op amp's out-of-range voltage on accuracy?
An out-of-phase voltage is the difference in voltage at which the output is not zero when the signal at the input is zero. A large out-of-phase voltage reduces the accuracy of a system, especially in high-gain applications, and selecting an op amp with a low out-of-phase voltage can improve accuracy.
-
4. What are the application scenarios of buffer amplifiers?
Buffer amplifiers are commonly used in signal isolation, impedance matching, voltage follower and power amplification scenarios, and are suitable for protecting weak signal sources from load effects in signal processing chains.

