L717TWC17W5PP3SY vs DBM21W1SN

Part Number
L717TWC17W5PP3SY
DBM21W1SN
Category D-Sub Connectors D-Sub Connectors
Manufacturer Amphenol ICC (Commercial Products) Amphenol ICC (FCI)
Description CONN D-SUB PLUG 17POS VERT SLDR CONN D-SUB RCPT 21P STR SLDR CUP
Package - -
Series TW DMW HE507
Features Grounding Indents -
Mounting Type Panel Mount, Through Hole Free Hanging (In-Line)
Termination Solder Solder Cup
Current Rating 7.5A 7.5A
Contact Finish Gold Gold
Number of Positions 17 (12 + 5 Power) 21 (20 + 1 Power)
Connector Type Plug, Male Pins Receptacle, Female Sockets
Contact Finish Thickness 16µin (0.40µm) -
Number of Rows 2 2
Connector Style D-Sub, Combo D-Sub, Combo
Contact Type Signal and Power Signal and Power (Not Included)
Flange Feature Housing/Shell (Unthreaded) Housing/Shell (Unthreaded)
Shell Material, Finish Steel, Tin Plated Steel, Yellow Cadmium Plated
Shell Size, Connector Layout 4 (DC, C) - 17W5 3 (DB, B) - 21W1
Material Flammability Rating - UL94 V-0
  • 1. What is a D-SUB connector

    The name of the D-SUB connector comes from the D-shaped appearance of its plug. It is a double-row cable connector widely used in computer, industrial automation and communication fields. This connector consists of two parts: a plug and a socket. It is connected through pinholes and pins. It can transmit video, audio and digital signals and provide a large number of grounding points.
    The D-SUB connector is a compact and versatile connector mainly used to support power, analog, RF or digital signal transmission. It has a variety of models, options and accessories and is a very economical interconnection solution.

  • 2. FAQ of D-SUB Connector

    ‌D-SUB connector connection is poor

    Performance: shell damage, bayonet connector loose or stuck after plugging.
    Cause: internal defects of the connector, external force damage.
    Solution: Check and repair internal defects of the connector and avoid external force damage.

    ‌D-SUB connector oxidation What are the manifestations?

    Performance: increased contact resistance.
    Cause: environmental factors and current effects.
    Solution: Clean and maintain the connector regularly, and use a protective cover to avoid pin exposure.

    ‌‌What problems are caused by deformation of D-SUB connector?

    Performance: Affects contact area and stability.

    Cause: Mechanical pressure or temperature change.

    Solution: Avoid excessive mechanical pressure and check connector status regularly.

  • 3. FAQ of D-SUB Connector

    ‌What is the reason for no signal in D-SUB connector?
    Performance: No signal.

    Solution: Check whether the signal cable is plugged in properly and ensure stable connection. 3.

    ‌‌D-SUB connector causes the monitor to fail to display.
    Performance: The monitor cannot display.
    Solution: Adjust the computer resolution to the highest resolution supported by the monitor.

    ‌‌What is the reason for poor connection of D-SUB connector?
    Performance: Poor connection.

    Cause: The pin is exposed and easily damaged.
    Solution: Use a protective cover to avoid pin exposure and operate carefully.

  • 4. FAQ of D-SUB Connector

    ‌What is the reason for slow data transmission of D-SUB connector?
    Performance: Slow or interrupted data transmission.
    Cause: Inherent characteristics of serial communication.
    Solution: Use faster communication standards or increase communication stability measures ‌24.

    ‌‌D-SUB connector signal attenuation
    Symptom: Signal attenuation.
    Cause: Long-distance transmission characteristics.
    Solution: Use higher quality cables or add signal amplifiers.