Part Number
L777DFE09PF179A
FCE17E09SC440
Category D-Sub Connectors D-Sub Connectors
Manufacturer Amphenol ICC (Commercial Products) Amphenol ICC (Commercial Products)
Description CONN D-SUB PLUG 9POS PNL MNT WW CONN D-SUB RCPT 9POS R/A SOLDER
Package - -
Series DF FCE17
Features Grounding Indents Board Lock, Filter
Mounting Type Panel Mount, Through Hole Through Hole, Right Angle
Termination Wire Wrap Solder
Current Rating 7.5A 5A
Contact Finish Gold Gold
Number of Positions 9 9
Connector Type Plug, Male Pins Receptacle, Female Sockets
Contact Finish Thickness 30µin (0.76µm) 15µin (0.38µm)
Number of Rows 2 2
Connector Style D-Sub D-Sub
Contact Type Signal Signal
Flange Feature Housing/Shell (Unthreaded) Housing/Shell (4-40)
Shell Material, Finish Steel, Tin Plated Steel, Tin Plated
Material Flammability Rating UL94 V-0 UL94 V-0
Shell Size, Connector Layout 1 (DE, E) 1 (DE, E)
  • 1. Specifications and models of D-SUB connectors

    There are many specifications and models of D-SUB connectors, and the common ones are D-SUB 9-pin, D-SUB 15-pin, D-SUB 25-pin and other series. These series have their own scope of application and characteristics. Users can choose the appropriate specifications and models according to actual needs. At the same time, the prices of different specifications and models are also different. Users need to consider factors such as cost and applicability when choosing.

  • 2. Problems caused by poor contact of D-SUB connectors

    Performance: increased contact resistance, circuit breakage, contact curtain movement, etc.

    Causes: inadequate connection, insufficient contact area, dirt, corrosion, oxidation, etc.
    Solution: Re-plug the connector, clean the connection part (use alcohol or other cleaning agents), replace the contact or connector.

  • 3. ‌D-SUB connector insulation is poor

    Performance: short circuit, insulation resistance is too poor.

    Cause: high humidity in the use environment, serious pollution, water or other liquids penetrate into the insulator, etc.
    Solution: Improve the use environment, clean the inside of the insulator, and replace the insulator.

  • 4. FAQ of D-SUB Connector

    ‌What is the reason for no signal in D-SUB connector?
    Performance: No signal.

    Solution: Check whether the signal cable is plugged in properly and ensure stable connection. 3.

    ‌‌D-SUB connector causes the monitor to fail to display.
    Performance: The monitor cannot display.
    Solution: Adjust the computer resolution to the highest resolution supported by the monitor.

    ‌‌What is the reason for poor connection of D-SUB connector?
    Performance: Poor connection.

    Cause: The pin is exposed and easily damaged.
    Solution: Use a protective cover to avoid pin exposure and operate carefully.