TLV2186IDSGT vs RC4157M

Part Number
TLV2186IDSGT
RC4157M
Category Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps
Manufacturer Texas Instruments Fairchild Semiconductor
Description LOW POWER, RAIL-TO-RAIL INPUT AN OPERATIONAL AMPLIFIER
Package Cut Tape (CT) Bulk
Series Zero-Drift -
Operating Temperature -40°C ~ 125°C (TA) 0°C ~ 70°C
Mounting Type Surface Mount Surface Mount
Package / Case 8-WFDFN Exposed Pad 14-SOIC (0.154\", 3.90mm Width)
Supplier Device Package 8-WSON (2x2) 14-SOIC
Current - Supply 90µA 5mA
Output Type Rail-to-Rail -
Number of Circuits 2 4
Voltage - Supply, Single/Dual (±) 4.5V ~ 24V, ±2.25V ~ 12V 20V
Current - Output / Channel 20 mA 25 mA
-3db Bandwidth - -
Amplifier Type Zero-Drift General Purpose
Current - Input Bias 100 pA 60 nA
Voltage - Input Offset 10 µV 1 mV
Slew Rate 0.35V/µs 1.6V/µs
Gain Bandwidth Product 750 kHz 19 MHz
  • 1. What is the difference between an instrumentation amplifier and an operational amplifier?

    Instrumentation amplifiers integrate multi-stage operational amplifiers for precise amplification of differential signals, while operational amplifiers are more versatile and can perform a wide range of analog signal processing tasks. Instrumentation amplifiers have higher input impedance and better common mode rejection.

  • 2. What is Common Mode Rejection Ratio (CMRR) and why is it important for instrumentation amplifiers?

    CMRR indicates an instrumentation amplifier's ability to suppress common mode signals, with higher values being better. A high CMRR is especially important in noisy environments to ensure that the amplifier primarily amplifies differential signals and is not affected by common mode interference.

  • 3. How do instrumentation amplifiers handle sensor signals?

    Instrumentation amplifiers are used to extract low-level signals from sensors (e.g. thermocouples, pressure sensors) to provide high-precision amplification, and are particularly suited to applications that require accurate reading and amplification of weak signals, such as medical and industrial monitoring.

  • 4. What are the main application scenarios of Op Amps?

    Operational amplifiers are widely used in signal conditioning, voltage follower, filter, comparator, integrator, differentiator, precision level shifter and other circuits, which are widely used in consumer electronics, industrial automation, and instrumentation.