GTCS25-301M-R02-2

Littelfuse Inc. GTCS25-301M-R02-2

The picture is for reference only, please refer to the product specification

  • GTCS25-301M-R02-2
  • Littelfuse Inc.
  • GDT 300V 20% 2.5KA SURFACE MOUNT
  • Gas Discharge Tube Arresters (GDT)
  • GTCS25-301M-R02-2 Datasheet
  • 2-SMD Cylinder Square End
  • 2-SMD Cylinder Square End
  • Lead free / RoHS CompliantLead free / RoHS Compliant
  • 7597
  • Spot Inventory / Athorized Dstributor / Factory Excess Stock
  • 1 year quality assurance 》
  • Click to get rates

What is GTCS25-301M-R02-2

Littelfuse Inc. Part Number GTCS25-301M-R02-2Gas Discharge Tube Arresters (GDT)), developed and manufactured by Littelfuse Inc., distributed globally by Jinftry. We distribute various electronic components from world-renowned brands and provide one-stop services, making us a trusted global electronic component distributor.

GTCS25-301M-R02-2 is one of the part numbers distributed by Jinftry, and you can learn about its specifications/configurations, package/case, Datasheet, and other information here. Electronic components are affected by supply and demand, and prices fluctuate frequently. If you have a demand, please do not hesitate to send us an RFQ or email us immediately [email protected] Please inquire about the real-time unit price, Data Code, Lead time, payment terms, and any other information you would like to know. We will do our best to provide you with a quotation and reply as soon as possible.

GTCS25-301M-R02-2 Specifications

  • Part NumberGTCS25-301M-R02-2
  • CategoryGas Discharge Tube Arresters (GDT)
  • ManufacturerLittelfuse Inc.
  • DescriptionGDT 300V 20% 2.5KA SURFACE MOUNT
  • Package2-SMD Cylinder Square End
  • SeriesGTC
  • Mounting TypeSurface Mount
  • Package / Case2-SMD Cylinder Square End
  • Tolerance±20%
  • Number of Poles1
  • Voltage - DC Spark Over (Nom)300V
  • Impulse Discharge Current (8/20µs)2500A (2.5kA)
  • Fail ShortNo

Application of GTCS25-301M-R02-2

Gas discharge tubes have a wide range of applications and play an important role in many industries. In the field of communications, gas discharge tubes are often used for lightning protection, such as lightning arresters and antenna switch tubes, to effectively protect equipment from overvoltage damage. In addition, in lighting technology, gas discharge tubes are also important light source components, such as fluorescent lamps and xenon flash lamps, which are favored for their high efficiency, long life and uniform spectrum characteristics. At the same time, in the fields of laser technology, medical equipment, photoelectric sensors, gas discharge tubes also play an irreplaceable role, providing strong support for technological progress in these fields.

GTCS25-301M-R02-2 Datasheet

GTCS25-301M-R02-2 Datasheet , 2-SMD Cylinder Square End,GTC,Surface Mount,2-SMD Cylinder Square End,±20%,1,300V,2500A (2.5kA),No

GTCS25-301M-R02-2 Classification

Gas Discharge Tube Arresters (GDT)

Gas Discharge Tube Arresters (GDT). It is a gap type lightning protection component, which has been widely used in lightning protection of communication system. The core principle is that through the effect of applied electric field, the gas medium in the tube is ionized, and then forms a conductive channel to allow the current to pass through, specifically, the gas discharge tube refers to a type of lightning arrester or antenna switch tube for overvoltage protection, and there are two or more electrodes in the tube. The interior is full of electrically stable inert gas (argon, neon). When a sufficient voltage is applied between the electrodes of the discharge tube to exceed the insulation strength of the inert gas, the two poles will produce an arc and ionize the gas, then the discharge tube will change from an insulating state to a conductive state.

FAQ about Gas Discharge Tube Arresters (GDT)

  • 1. What is a gas discharge tube arrester?

    A gas discharge tube arrester is a device that uses the principle of gas discharge to achieve overvoltage protection. It is mainly composed of a ceramic sealed discharge tube, which contains two or more metal electrodes with gaps and is filled with inert gas such as argon or neon. When the external voltage exceeds the breakdown voltage of the discharge tube, the gas in the tube is ionized under the action of the electric field to form a conductive channel, which quickly discharges the large current and high voltage generated by the lightning strike, thereby protecting the subsequent circuit from damage. Once the overvoltage disappears, the discharge tube will return to a high-resistance insulation state, waiting for the next impact.

  • 2. What is a GDT gas discharge tube?

    A GDT gas discharge tube (Gas Discharge Tube) is a device used to protect electronic equipment from transient voltage damage. It is mainly composed of one or more discharge gaps, sealed in a ceramic cavity or glass tube filled with inert gas. Under normal working conditions, the GDT maintains a high resistance state; when the voltage exceeds its breakdown voltage, the gas in the gas discharge tube is ionized to form a conductive path, which introduces the surge current into the ground, thereby protecting the equipment. Once the overvoltage disappears, the GDT returns to a high impedance state and waits for the next shock.
    Working Principle
    The working principle of GDT is based on the gas discharge phenomenon. Under normal operating voltage, the inert gas inside the GDT remains non-conductive and the device is in a high impedance state. When the voltage reaches or exceeds its breakdown voltage, the gas ionizes to form a plasma path, causing the GDT to present a low impedance state, directing the surge current into the ground, thereby protecting the device. After the overvoltage disappears, the GDT returns to a high impedance state.

  • 3. How does GDT work?

    The working principle of GDT (gas discharge tube) is mainly based on its electrical characteristics, which are determined by the type of gas, pressure and electrode distance. The GDT is filled with inert gas (such as neon or argon) and maintains a certain pressure. When the voltage across the GDT rises to a value greater than its discharge voltage, the gas begins to ionize, causing the discharge tube to conduct, changing from a high impedance state to a low impedance state, thereby rapidly reducing the voltage across the two ends.
    The working process of GDT can be divided into the following stages:
    Insulation state: When there is no surge, GDT is in an open circuit state, which is equivalent to a high-impedance insulator with a very large resistance (usually greater than 1000 megohms), almost no leakage current or very small leakage current.
    Discharge state: When the voltage across the GDT rises to a value greater than its discharge voltage, the gas begins to ionize and the discharge tube is turned on. At this time, the GDT changes from a high-impedance state to a low-impedance state, causing the voltage across its two ends to drop rapidly, usually by tens of volts.
    Follow-current effect: Due to the follow-current characteristics of the gas discharge tube, even if the surge voltage disappears, as long as a certain voltage (usually above 15V) is maintained at both ends, the GDT will remain in the on state and continue to conduct electricity.
    The application scenarios of GDT mainly include lightning surge protection, which is suitable for lightning protection of AC and DC power supplies and signal circuits. It can quickly turn on when a surge arrives, limit the voltage peak, and protect the connected electronic equipment from damage.

• Prompt Responsiveness

• Guaranteed Quality

• Global Access

• Competitive Market Price

• One-Stop support services of supply chain

Jinftry, Your most trustworthy component supplier, welcome to send us the inquiry, thank you!

Do you have any questions about GTCS25-301M-R02-2 ?
Feel free to contact us:

+86-755-28503874
+8615019224070, annies65, +8615118125813
568248857, 827259012, 316249462
+8615019224070, +8615118118839, +8615118125813
( Email first will be appreciative )

Customer reviews

Post your comment

Littelfuse Inc.
Littelfuse Inc.
Littelfuse is a leading global company specializing in circuit protection, power control, and sensing technology manufacturing.
In 1927, Littelfuse was founded in Illinois, USA. The company's products mainly include circuit protection devices (fuses, resistors,...
GTCS25-900M-R02
GTCS25-900M-R02

GDT 90V 20% 2.5KA SURFACE MOUNT

GTCA38-501M-R10
GTCA38-501M-R10

GDT 90V 20% 2.5KA SURFACE MOUNT

GTCR38-231M-R10
GTCR38-231M-R10

GDT 90V 20% 2.5KA SURFACE MOUNT

GTCA38-900M-R10
GTCA38-900M-R10

GDT 90V 20% 2.5KA SURFACE MOUNT

GTCA35-750M-R05
GTCA35-750M-R05

GDT 90V 20% 2.5KA SURFACE MOUNT

SL1411A075A
SL1411A075A

GDT 90V 20% 2.5KA SURFACE MOUNT

SE350
SE350

GDT 90V 20% 2.5KA SURFACE MOUNT

GTCS28-471M-R10-2
GTCS28-471M-R10-2

GDT 90V 20% 2.5KA SURFACE MOUNT

Electronic Parts Index
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
1
2
3
4
5
6
7
8
9
Shopping Cart Tel: +86-755-28503874 Email: [email protected] Skype: +8615019224070, annies65, +8615118125813 QQ: 568248857, 827259012, 316249462 Mobile: +8615019224070, +8615118118839, +8615118125813 WeChat: Send Message
TOP