MCP6292-H/MS vs INA185A1IDRLT

Part Number
MCP6292-H/MS
INA185A1IDRLT
Category Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps Linear - Amplifiers - Instrumentation, OP Amps, Buffer Amps
Manufacturer Microchip Technology Texas Instruments
Description IC OPAMP GP 2 CIRCUIT 8MSOP IC CURR SENSE 1 CIRCUIT SOT563
Package Tape & Reel (TR) -Reel®
Series - -
Operating Temperature -40°C ~ 150°C (TA) -40°C ~ 125°C (TA)
Mounting Type Surface Mount Surface Mount
Package / Case 8-TSSOP, 8-MSOP (0.118\", 3.00mm Width) SOT-563, SOT-666
Supplier Device Package 8-MSOP SOT-563
Current - Supply 1mA (x2 Channels) 200µA
Output Type Rail-to-Rail Rail-to-Rail
Number of Circuits 2 1
Voltage - Supply, Single/Dual (±) 2.4V ~ 6V 2.7V ~ 5.5V
Current - Output / Channel 25 mA -
-3db Bandwidth - -
Amplifier Type General Purpose Current Sense
Current - Input Bias 1 pA 75 µA
Voltage - Input Offset 3 mV 100 µV
Slew Rate 7V/µs 2V/µs
Gain Bandwidth Product 10 MHz 350 kHz
  • 1. What is the difference between an instrumentation amplifier and an operational amplifier?

    Instrumentation amplifiers integrate multi-stage operational amplifiers for precise amplification of differential signals, while operational amplifiers are more versatile and can perform a wide range of analog signal processing tasks. Instrumentation amplifiers have higher input impedance and better common mode rejection.

  • 2. How do instrumentation amplifiers handle sensor signals?

    Instrumentation amplifiers are used to extract low-level signals from sensors (e.g. thermocouples, pressure sensors) to provide high-precision amplification, and are particularly suited to applications that require accurate reading and amplification of weak signals, such as medical and industrial monitoring.

  • 3. What is the effect of the op amp's out-of-range voltage on accuracy?

    An out-of-phase voltage is the difference in voltage at which the output is not zero when the signal at the input is zero. A large out-of-phase voltage reduces the accuracy of a system, especially in high-gain applications, and selecting an op amp with a low out-of-phase voltage can improve accuracy.

  • 4. What are the application scenarios of buffer amplifiers?

    Buffer amplifiers are commonly used in signal isolation, impedance matching, voltage follower and power amplification scenarios, and are suitable for protecting weak signal sources from load effects in signal processing chains.

Shopping Cart Tel: +86-755-28503874 Email: [email protected] Skype: +8615019224070, annies65, +8615118125813 QQ: 568248857, 827259012, 316249462 Mobile: +8615019224070, +8615118118839, +8615118125813 WeChat: Send Message
TOP